Watch Fireproof Online

Watch Online romance Movies HD Free with Subtitles Free Streaming romance Movies HD online Full Movies HD with Subtitles Free Streaming Online Movies HD streaming. Courageous is the first single from Casting Crowns new album, Come To The Well, now available in stores and online. Preview purchase on iTunes http. Myths about Fireproof Gun Safe Fire Ratings. To save costs, most gun safe manufactures use 1. Sheetrock as fire lining and then charge you a premium for it. Fireproof gun safes offer mediocre fire protection and can not meet industry standard tests for fireproof safes. So, gun safe manufactures basically make up their own ratings out of thin air. It is basically useless to compare gun safe fire ratings from different manufactures. This article will show you the truth about gun safe fire ratings so that you dont overpay for protection youre not really getting. Gun safes offer less protection than you think much less. Burned Up Shotgun and Revolver. MV5BMzI2NDAzNzc4N15BMl5BanBnXkFtZTcwMjE4MDk0Mg@@._V1_SX300.jpg' alt='Watch Fireproof Online' title='Watch Fireproof Online' />It goes without saying that no safe is truly fireproof, every safe has its limit and will fail at some point depending on how its constructed. There are many variables when it comes to fires, no two are the same. In most home fires where the walls collapsed, the contents of fireproof gun safe have totally burned up. But you can also find some examples where cheap fireproof gun safes made it through less serious fires with no loss. In some fires, gun safes with thick steel but absolutely no fire insulation survived. It all depends on the details of the specific fire. Look closely at after fire pictures. The remaining structure and fact that the lock wasnt melted off indicate that this gun safe didnt get too hot. Even so, the interior of the door shows heavy fire damage. Because of the variability from fire to fire, it is difficult to determine how much protection a gun safe gives you by looking at what happened in specific fires. This is why standardized fire ratings are so important. These independent tests are designed to emulate a common worst case scenario to give your valuables the best chance of surviving regardless of the type of fire. There is a well respected fire rating standard in the safe industry, lets take a look at it. A Real Fire Safe Rating  UL 7. Underwriters Laboratories UL 7. Test for Fire Resistance of Record Protection Equipment, including safes. UL 7. 2 Classes. There are three classes depending on what you are protecting. UL 7. 2 Class. Inside of Safe Must Stay Below. Designed to Protect. Class 3. 50. 35. 0 FPaper. Class 1. 50. 15. 0 F8. Relative Humidity. Watch The Harvesting Online Free HD more. All above and non paper records such as computer disks and photos. Class 1. 25. 12. 5 F8. Relative Humidity. All above and flexible computer disks. UL 7. 2 Duration. UL Rated Fire Safe protected electronic media in a moderate office fire. For each class, there is an associated time rating  3. Note that this time rating is not the length of the actual test the actual UL 7. UL 7. 2 Ratings. There are four types of test which may be performed for UL 7. Fire Endurance Test This is the standard fire protection test. Fire and Impact Test An additional test where the safe is dropped from 3. Note that in a fire, heavy beams and other items may also fall on a safe. So, impact resistance is important for a number of reasons. Explosion Hazard Test Required test to ensure that the safe will not explode in a rapid heating situation from the buildup of pressure inside the safe or safe walls. Combined Explosion and Impact Test. UL 7. 2 Test Procedure. What goes into a real fire testFire Endurance Test Procedure. UL 7. 2 Fire Endurance Test oven temperature ramp. Safe to be tested is loaded with loosely distributed paper andor computer media. To measure interior temperature, the safe is fitted with thermocouples at the bottom, at the top, and all four side walls. For Class 1. 50 or 1. Class 1. 50 or 1. This ensures the safe interior at the start of the test is between 6. F with relative humidity below 6. The safe is placed in the oven. The oven temperature is increased at a carefully monitored rate shown in the Oven Temperature Ramp plot. Care is taken to make sure the heat is distributed equally to all six sides of the safe. After the final temperature of the test is reached e. F for a 2 hour rating, the oven is shut off. The test continues as the safe is left in the oven. The oven remains unopened and is still very hot. The safe remains in the oven for up to 6. Only safes whose internal temperature and humidity for Class 1. UL Listed. The safe is opened and the contents are examined to see if theyre still in usable condition. The safe interior components and walls are examined for heat and humidity damage. To keep the UL label, a sample safe may be pulled out of production one year later and retested. Many safes fail the UL 7. Step 7.  Left inside the hot oven, the safe is still absorbing heat even after the oven is switched off. This situation is similar to a real fire,  where after the fire is put out, the safe remains in the smoldering remains absorbing heat. Fire and Impact Test Procedure. If requested by the manufacturer, after the safe passes the Fire Endurance Test, another sample can be tested for Impact. Safe is prepared as in the Fire Endurance Test. Safe is placed in an oven and heated for the duration shown in the table. Within 2 minutes, the safe is removed from the oven and dropped from a height of 3. The safe is examined for cracking of fire insulation and opening of interior walls. The safe is placed back in the oven upside down to simulate landing in different orientations after a fall. The safe is re heated again based on the specifications in the table below. After the specified duration, the safe is allowed to cool, then taken apart to examine the internal condition, fire insulation, locks, and the condition of the contents. To keep the UL label, a sample safe may be pulled out of production one year later and retested. Fire Endurance Test Rating All ClassesImpact Test Oven Temperature. Impact Test Heating Time. Minute. 14. 60 F2. Hour. 15. 50 F3. Hour. F4. Hour. 17. 00 F6. Hour. 17. 00 F6. Explosion Test Procedure. All safes tested for Fire Resistance must pass the Explosion Test. Safe is prepared as in the Fire Endurance Test, but left outside of the oven. The test oven is preheated to 2. F. The oven door is opened and the safe quickly put inside and the door closed. The oven remains heated for 3. No explosion can occur. The safe is opened and examined. The manufacturer may elect to combine the Impact and Explosion tests. UL will heat the safe for the explosion test, then drop it, reheat it and cool it. The cost of having a UL 7. Once a safe model has passed UL 7. UL will allow the rating to apply to identically constructed units 5. This cost is required whether or not the safe pass the test. Multiple tests at repeated expense may be required before the manufacturer finally gets it right. This represents a substantial investment on the part of the manufacturer. If you buy a safe with a UL 7. Fire Endurance rating, you can have confidence that you have a good level of protection in a fire. Unfortunately, virtually no gun safes are UL 7. Listed.   Those that are UL 7. B Rate or higher burglary ratings. As you can see UL 7. To meet these stringent requirements, fireproof safes must be well built. True Fire Safe Construction. Due to the expense of testing, the design of UL 7. Instead these safes use conservative, tried and true construction methods, much like your favorite firearms. AMSEC Pouring Fireproofing. The vast majority of true fire safes use a true composite construction fully welded inner and outer steel shells with a poured concrete amalgamate fireproofing in between. During pouring, the safe is vibrated on a shake table to get out the air bubbles. Then the fireproofing is baked in an oven and allowed to harden. Once hardened, the fireproofing directly supports the weight of the safe and interior contents. There is no need for steel frames and supports, which can transmit heat from the outside to the safes inside in a fire. During construction, the inner shell is supported by spot welded barrier contact pins, which temporarily hold the inner shell in place while the fireproofing material is poured.